Rapid temperature change rate of 5C/min to 15C/min with humidity test chamber

Rapid temperature change rate of 5C/min to 15C/min with humidity test chamber

DESCRIPTION

High stress of 5C/min~15C/min. This faster temperature (& humidity) chamber enables the application of high stress to the specimen at a rapid temperature change rate of 5C/min. or more. Due to the larger refrigeration system 5C/min. or more are achieved from -45C to +155C with the F-TH and F-HL models (with or without specimen loaded).

 

Instrumentation integrated into the door To minimize the required installation space for the device, the instrumentation section has been integrated into the door. The controller unit is integrated on a bright and color LCD interactive touch-screen system which provides easy controlling of the chamber.


Inquire Now
Description

Fast Temperature Change Rate Test Chamber

F-TH-150 / 225 / 408 / 800 (A~F) — Rapid 3–20 °C/min Linear Ramp, Optional Humidity Control

CE Certified 12-Month Warranty Built to Order Lifetime Remote Support Manufacturer Since 1988

F-TH Series — Four Model Comparison

Parameter F-TH-150 (A~F) F-TH-225 (A~F) F-TH-408 (A~F) F-TH-800 (A~F)
Internal Dimension W×H×D (mm) 500 × 600 × 500 600 × 750 × 500 600 × 850 × 800 1000 × 1000 × 800
External Dimension W×H×D (mm) 1100 × 1750 × 1600 1200 × 1800 × 1700 1250 × 1900 × 1900 1600 × 2050 × 2150
Temperature Range −70 °C ~ +150 °C
Range of Fast Temperature Change −45 °C ~ +85 °C
Maximum Ramp Rate Up to 20 °C/min under full linear control
Rising / Falling Velocity Linear control: 3 ~ 20 °C/min, adjustable  |  Nonlinear control: 3 ~ 30 °C/min, adjustable
Humidity Range (Optional) 20% ~ 98% R.H. — 10%–98% or 5%–98% available with dehumidifier
Indication Resolution 0.1 °C / 0.1% R.H.
Distribution Uniformity ± 2.0 °C / ± 3.0% R.H.
Control Accuracy ± 0.5 °C / ± 2.5% R.H.
Internal and External Material Inner box: SUS 304# stainless steel. Outer box: stainless steel or cold-rolled steel with paint coating.
Insulation Material High-temperature resistant, high-density, formate chlorine / ethyl acetate foam insulation materials
Cooling System Water-cooled / single-stage compressor; environmentally friendly refrigerant R23 / R404A
Compressor French Tecumseh brand; Germany Bizer brand
Protection Devices Fuse-free switch; compressor overload protection; high/low pressure coolant protection; over-humidity and over-temperature protection; fuses; fault warning system; water shortage warning
Optional Accessories Inner door with operation hole; water purifier; dehumidifier; recorder
Communication RS-232 or RS-485
Power AC 380 V 3-phase 5-wire, 50/60 Hz
Weight (Approx.) 250 kg 350 kg 450 kg 600 kg
A~F suffixes indicate configurable options. Humidity function is optional and requires a dehumidifier for the 5%–10% R.H. range. Custom chamber sizes available on request.

Need a different chamber size, humidity range, or a specific test standard? Send us your DUT spec and test profile — our team will recommend a configuration and quote within 24 hours.

Product Gallery

Product Images

Production Facility

Assembly & Workshop

Each chamber is assembled, wired, and functionally tested in our own facility before shipment.

Configurations

Two Control Modes & Optional Humidity

Match the ramp profile and humidity capability to your test standard — the chamber is built to your specification.

Linear Mode

3–20 °C/min with Full Linear Control

A constant ramp rate from start to finish. This is the mode used for standards that define a fixed rate per minute — for example, certain automotive and battery cycling profiles.

  • Adjustable from 3 to 20 °C per minute
  • Constant slope — no drift across the full cycle
  • Repeatable and comparable across tests
  • Preferred for qualification reports and audits
Nonlinear Mode

3–30 °C/min with Faster Peak Ramp

Ramp rate varies across the profile. This mode is used for accelerated stress screening, where the goal is to force failures as fast as the chamber allows.

  • Adjustable from 3 to 30 °C per minute
  • Fastest pull-down and pull-up performance
  • Suited for HALT-style screening and stress testing
  • Humidity function can be combined
Features

What This System Delivers

Speed

Up to 20 °C/min Linear Ramp

In practice: Compresses what would be a 3–5 hour gradual test into a much shorter cycle — without sacrificing the linear profile that standards require.

Coverage

Temperature + Optional Humidity

In practice: Run dry heat / cold cycling, or add humidity control from 20% to 98% R.H. without buying a second chamber.

Accuracy

±0.5 °C / ±2.5% R.H. Control

In practice: BTHC-based control keeps both temperature and humidity stable — including during high-speed ramp events where drift usually appears.

Flexibility

4 Standard Volumes, A~F Configurable

In practice: 150L, 225L, 408L, and 800L internal sizes, each configurable across A~F option levels — from basic cycling to full humidity control.

Key Features

Built-in Functions

Control, cycling, and monitoring features included with every fast temperature change chamber.

01
BTHC Temperature & Humidity ControlBalanced temperature and humidity control with P.I.D. + S.S.R., plus auto-calculate function.
02
Programmable Multi-Segment CyclingUp to 100 programs, each with up to 100 segments; max 999 cycles per program.
03
Power-Off MemoryResumes from where the program stopped after power loss. 5-year memory backup.
04
Imported LCD DisplayShows set point, actual value, and time simultaneously. Fixed or programmable conditions.
05
Dual Refrigeration LoopImported fully-closed compressor; fast cooling, air-cooled or water-cooled configuration.
06
DIN PT-100Ω SensorStandard industrial temperature sensor for long-term stability and easy replacement.
07
RS-232 / RS-485 + Timer RelayStandard communication interface and timer signal output relay for automation.
08
Interface Lock & AlarmInterface lock function prevents unauthorized changes; alarm triggers on running or setting faults.
Standards

Common Test Standards

The F-TH Series is designed to support the following rapid temperature and humidity cycling standards.

IEC 62133-2017Secondary Cells & Batteries
UL 1642Lithium Batteries
UN 38.3Transport of Lithium Batteries
IEC 60068-2-14Change of Temperature
GB/T 2423.22Change of Temperature
IEC 60068-2-38Composite Temperature / Humidity
MIL-STD-810Environmental Test
ISO 16750-4Road Vehicles — Climatic Loads
Test Data

Measured Performance Data

Temperature and humidity profiles recorded from the F-TH Series during real rapid-cycling tests.

Charts show temperature and humidity profiles recorded during a typical rapid temperature change cycle.

Safety

Multi-Layer Protection

Independent protection layers — protecting your sample, your operator, and the system.

Fuse-free switch
Compressor overload protection
High / low pressure coolant switch
Over-humidity protection
Over-temperature protection
Fault warning system
Water shortage warning
Fuses & electronic alarm
Applications

Who Uses This System

Applied to quality inspection and reliability testing across electronics, automotive, battery, and material industries.

Electronics & PCBs
Electric Appliances
Communication Equipment
Instrument & Meters
Automotive Components
Battery & Energy Storage
Plastic & Rubber
Metal & Alloys
Food & Chemical
Building Materials
Medical Devices
Aerospace & Defense
FAQ

Common Questions

What is the difference between linear and nonlinear ramp control?
Linear control holds a constant ramp rate from start to finish — 3 to 20 °C/min adjustable. Nonlinear control allows a faster peak rate of 3 to 30 °C/min but is not constant across the full cycle. Linear mode is used for standardized profiles; nonlinear mode is used for accelerated stress screening.
Is humidity control included as standard?
Humidity is optional. The standard humidity range is 20%–98% R.H. For the wider 10%–98% or 5%–98% ranges, a dehumidifier is required and must be specified in the order.
What does the A~F suffix on the model number indicate?
The A~F suffixes indicate configurable option levels on each chassis size. Options include humidity control, inner door with operation hole, water purifier, dehumidifier, and recorder. Send us your test profile and we will confirm the correct option level.
What is the lead time?
All chambers are built to order. Typical lead time is approximately 30–40 working days, depending on configuration and customization. Exact lead time is confirmed in the quotation.
Do you offer installation and commissioning?
All systems ship with export packing and an installation guide. Remote commissioning support is included for overseas customers. On-site installation can be arranged and quoted separately based on location.
What warranty is included?
Every system carries a 12-month warranty. Lifetime remote technical support is included. Extended warranty is available on request.
Ready to specify your chamber? Send us your test standard, sample size, and required ramp rate.